Rewrite industrialtest.api.createNetworkMap and few other network related features
This commit is contained in:
@@ -20,13 +20,16 @@ local S=minetest.get_translator("industrialtest")
|
||||
-- \param capacity How much EU item/node can store
|
||||
-- \param flow How much EU can flow in or out item/node per industrialtest.updateDelay
|
||||
-- \param ioConfig Input/Output configuration in following side order: -X, +X, -Y, +Y, -Z, +Z
|
||||
-- a - bidirectional, i - input, o - output
|
||||
-- a - bidirectional, i - input, o - output.
|
||||
-- Instead of string containing IO mode for each side, ioConfig can hold a table for each side, containing
|
||||
-- IO mode and flow override
|
||||
-- \returns nil
|
||||
function industrialtest.api.addPowerStorage(meta,capacity,flow,ioConfig)
|
||||
meta:set_int("industrialtest.powerCapacity",capacity)
|
||||
meta:set_int("industrialtest.powerFlow",flow)
|
||||
meta:set_int("industrialtest.powerAmount",0)
|
||||
meta:set_string("industrialtest.ioConfig",ioConfig)
|
||||
meta:set_int("industrialtest.extendedIoConfig",type(ioConfig)~="string")
|
||||
meta:set_string("industrialtest.ioConfig",type(ioConfig)=="string" and ioConfig or minetest.serialize(ioConfig))
|
||||
end
|
||||
|
||||
-- \brief Checks if metadata contains power storage
|
||||
@@ -42,15 +45,49 @@ function industrialtest.api.hasPowerStorage(meta)
|
||||
return true
|
||||
end
|
||||
|
||||
-- \brief Checks if ioConfig from metadata is extended one. It exploits the fact that minetest.serialize returns Lua code
|
||||
-- which returns table, hence it can check for return at the beginning of the string
|
||||
-- \param meta MetaDataRef
|
||||
-- \returns bool
|
||||
function industrialtest.api.isExtendedIoConfig(meta)
|
||||
return meta:get_int("industrialtest.extendedIoConfig")==1
|
||||
end
|
||||
|
||||
-- \brief Returns ioConfig from metadata, deserializing it if it's extended one
|
||||
-- \param meta MetaDataRef
|
||||
-- \returns table or string
|
||||
function industrialtest.api.getIoConfig(meta)
|
||||
local ioConfig=meta:get_string("industrialtest.ioConfig")
|
||||
return industrialtest.api.isExtendedIoConfig(meta) and minetest.deserialize(ioConfig) or ioConfig
|
||||
end
|
||||
|
||||
-- \brief Changes node's power IO config. Function doesn't check if meta actually contains power storage.
|
||||
-- \param meta MetaDataRef of node which power IO config should be changed
|
||||
-- \param side Side number. See industrialtest.api.addPowerStorage to check order.
|
||||
-- \param mode Side mode. See industrialtest.api.addPowerStorage for possible values.
|
||||
-- \returns nil
|
||||
function industrialtest.api.changeIoConfig(meta,side,mode)
|
||||
local ioConfig=meta:get_string("industrialtest.ioConfig")
|
||||
ioConfig=string.sub(ioConfig,1,side-1)..mode..string.sub(ioConfig,side+1)
|
||||
meta:set_string("industrialtest.ioConfig",ioConfig)
|
||||
local ioConfig=industrialtest.api.getIoConfig(meta)
|
||||
if type(ioConfig)=="string" then
|
||||
ioConfig=string.sub(ioConfig,1,side-1)..mode..string.sub(ioConfig,side+1)
|
||||
meta:set_string("industrialtest.ioConfig",ioConfig)
|
||||
else
|
||||
ioConfig[side]=mode
|
||||
meta:set_string("industrialtest.ioConfig",minetest.serialize(ioConfig))
|
||||
end
|
||||
end
|
||||
|
||||
-- \brief Returns power flow for side
|
||||
-- \param meta MetaDataRef
|
||||
-- \param side number Side number
|
||||
-- \returns number
|
||||
function industrialtest.api.getPowerFlowForSide(meta,side)
|
||||
local ioConfig=industrialtest.api.getIoConfig(meta)
|
||||
if type(ioConfig)=="string" then
|
||||
return meta:get_int("industrialtest.powerFlow")
|
||||
else
|
||||
return ioConfig[side].flow
|
||||
end
|
||||
end
|
||||
|
||||
-- \brief Checks if provided side is power input
|
||||
@@ -58,9 +95,13 @@ end
|
||||
-- \param side Side number. See industrialtest.api.addPowerStorage to check order.
|
||||
-- \returns true if provided side is power input, false otherwise
|
||||
function industrialtest.api.isPowerInput(meta,side)
|
||||
local ioConfig=meta:get_string("industrialtest.ioConfig")
|
||||
local mode=string.sub(ioConfig,side,side)
|
||||
return (mode=="i" or mode=="a")
|
||||
local ioConfig=industrialtest.api.getIoConfig(meta)
|
||||
if type(ioConfig)=="string" then
|
||||
local mode=string.sub(ioConfig,side,side)
|
||||
return (mode=="i" or mode=="a")
|
||||
else
|
||||
return (ioConfig[side].direction=="i" or ioConfig[side].direction=="a")
|
||||
end
|
||||
end
|
||||
|
||||
-- \brief Checks if provided side is power output
|
||||
@@ -68,9 +109,13 @@ end
|
||||
-- \param side Side number. See industrialtest.api.addPowerStorage to check order.
|
||||
-- \returns true if provided side is power output, false otherwise
|
||||
function industrialtest.api.isPowerOutput(meta,side)
|
||||
local ioConfig=meta:get_string("industrialtest.ioConfig")
|
||||
local mode=string.sub(ioConfig,side,side)
|
||||
return (mode=="o" or mode=="a")
|
||||
local ioConfig=industrialtest.api.getIoConfig(meta)
|
||||
if type(ioConfig)=="string" then
|
||||
local mode=string.sub(ioConfig,side,side)
|
||||
return (mode=="o" or mode=="a")
|
||||
else
|
||||
return (ioConfig[side].direction=="o" or ioConfig[side].direction=="a")
|
||||
end
|
||||
end
|
||||
|
||||
-- \brief Checks if power storage is fully charged
|
||||
|
||||
Reference in New Issue