forked from mrkubax10/industrialtest
Add simple item fluid storage API
This commit is contained in:
74
api.lua
74
api.lua
@@ -151,6 +151,79 @@ industrialtest.api.afterToolUse=function(itemstack)
|
||||
meta:set_int("industrialtest.uses",uses)
|
||||
itemstack:set_wear(65535-uses/def.tool_capabilities.uses*65535)
|
||||
end
|
||||
|
||||
-- \brief Check if itemstack contains fluid storage
|
||||
-- \param itemstack ItemStack
|
||||
-- \returns bool
|
||||
industrialtest.api.itemHasFluidStorage=function(itemstack)
|
||||
local values={"industrialtest.fluidAmount","industrialtest.fluidCapacity"}
|
||||
local meta=itemstack:get_meta()
|
||||
for _,value in ipairs(values) do
|
||||
if not meta:contains(value) then
|
||||
return false
|
||||
end
|
||||
end
|
||||
return true
|
||||
end
|
||||
|
||||
-- \brief Updates itemstack description and wear depending on contained fluid
|
||||
-- \param itemstack ItemStack
|
||||
-- \returns nil
|
||||
industrialtest.api.updateItemFluidText=function(itemstack)
|
||||
local meta=itemstack:get_meta()
|
||||
local def=itemstack:get_definition()
|
||||
meta:set_string("description",S("@1\n@2 / @3",def.description,meta:get_int("industrialtest.fluidAmount"),meta:get_int("industrialtest.fluidCapacity")))
|
||||
itemstack:set_wear(65535-meta:get_int("industrialtest.fluidAmount")/meta:get_int("industrialtest.fluidCapacity")*65534)
|
||||
end
|
||||
|
||||
-- \brief Prepares itemstack containing fluid storage
|
||||
-- \param itemstack ItemStack
|
||||
-- \returns bool
|
||||
industrialtest.api.prepareFluidStorageItem=function(itemstack)
|
||||
local meta=itemstack:get_meta()
|
||||
local def=itemstack:get_definition()
|
||||
if industrialtest.api.itemHasFluidStorage(itemstack) or not def.groups or not def.groups._industrialtest_fluidStorage or not def._industrialtest_fluidCapacity then
|
||||
return false
|
||||
end
|
||||
meta:set_int("industrialtest.fluidAmount",100)
|
||||
meta:set_int("industrialtest.fluidCapacity",def._industrialtest_fluidCapacity)
|
||||
industrialtest.api.updateItemFluidText(itemstack)
|
||||
return true
|
||||
end
|
||||
|
||||
-- \brief Adds fluid amount to item fluid storage
|
||||
-- \param itemstack ItemStack
|
||||
-- \param amount number
|
||||
-- \returns number
|
||||
industrialtest.api.addFluidToItem=function(itemstack,amount)
|
||||
local meta=itemstack:get_meta()
|
||||
if not industrialtest.api.itemHasFluidStorage(itemstack) then
|
||||
return 0
|
||||
end
|
||||
local fluidAmount=meta:get_int("industrialtest.fluidAmount")
|
||||
local fluidCapacity=meta:get_int("industrialtest.fluidCapacity")
|
||||
local prevFluidAmount=fluidAmount
|
||||
fluidAmount=industrialtest.internal.clamp(fluidAmount+amount,0,fluidCapacity)
|
||||
meta:set_int("industrialtest.fluidAmount",fluidAmount)
|
||||
industrialtest.api.updateItemFluidText(itemstack)
|
||||
return fluidAmount-prevFluidAmount
|
||||
end
|
||||
|
||||
-- \brief Adds fluid to destination itemstack while subtracting it from source metadata
|
||||
-- \param srcMeta MetaDataRef
|
||||
-- \param itemstack ItemStack
|
||||
-- \param amount number
|
||||
-- \returns number
|
||||
industrialtest.api.transferFluidToItem=function(srcMeta,itemstack,amount)
|
||||
local flow=math.min(srcMeta:get_int("industrialtest.fluidAmount"),amount)
|
||||
if flow==0 then
|
||||
return 0
|
||||
end
|
||||
local actualFlow=industrialtest.api.addFluidToItem(itemstack,flow)
|
||||
srcMeta:set_int("industrialtest.fluidAmount",srcMeta:get_int("industrialtest.fluidAmount")-actualFlow)
|
||||
return actualFlow
|
||||
end
|
||||
|
||||
-- \brief Checks if power storage is fully charged
|
||||
-- \param meta MetaDataRef which should be checked
|
||||
-- \returns true if power storage is fully charged, false otherwise
|
||||
@@ -198,6 +271,7 @@ end
|
||||
-- \brief Adds power to destination itemstack while subtracting it from source metadata
|
||||
-- \param srcMeta MetaDataRef from which take power
|
||||
-- \param itemstack ItemStack to which add power
|
||||
-- \param amount number
|
||||
-- \returns How much of power was actually transferred
|
||||
industrialtest.api.transferPowerToItem=function(srcMeta,itemstack,amount)
|
||||
local currentFlow=math.min(srcMeta:get_int("industrialtest.powerAmount"),amount)
|
||||
|
||||
Reference in New Issue